How to turn on the wall-mounted boiler heating: Operation guide and analysis of frequently asked questions
As winter approaches, wall-hung boilers have become the core equipment for heating many homes. How to turn on the wall-mounted boiler heating correctly? This article will provide you with a structured how-to guide, along with data on recent hot topics for reference.
1. Steps to turn on the wall-mounted boiler heating

| steps | Operating Instructions | Things to note |
|---|---|---|
| 1. Check the equipment | Make sure the power is on and the gas valve is open | Professional debugging is required for first time use |
| 2. Inject water and pressurize | Open the water supply valve until the pressure gauge displays 1-1.5Bar | The pressure is too high and needs to be drained and relieved. |
| 3. Mode selection | Turn the knob to winter mode (snowflake icon) | Summer mode only provides hot water |
| 4. Temperature setting | It is recommended that the heating water temperature is 55-65℃ and the room temperature is 18-22℃ | Floor heating system does not exceed 50℃ |
| 5. Start running | Press the power button and wait for the system self-test to complete | Abnormal alarms need to be deactivated immediately |
2. Recent hot topics related to heating (last 10 days)
| Hot search keywords | heat index | Main discussion content |
|---|---|---|
| Wall-hung boiler energy-saving tips | 82,000 | Intermittent heating vs continuous low temperature operation |
| The radiator is not hot | 65,000 | Comparison of air blockage solutions |
| Floor heating cleaning | 58,000 | Advantages and Disadvantages of Chemical Cleaning and Physical Cleaning |
| Intelligent temperature control system | 43,000 | WIFI remote control experience sharing |
| Gas bills rising | 91,000 | Summary of subsidy policies in various provinces and cities |
3. Solutions to common problems
1. Abnormal system pressure:When the pressure is lower than 0.8Bar, water needs to be replenished, and when the pressure is higher than 2.5Bar, the pressure needs to be relieved through the exhaust valve. It is recommended to check the pressure gauge weekly.
2. The radiator is not hot locally:It may be caused by air blockage. You can use a screwdriver to open the exhaust valve (usually located in the upper right corner of the radiator) until the water comes out and close it.
3. Frequent starts and stops:Check whether the temperature sensor is blocked. It is recommended to keep 30cm of ventilation space around the device to avoid direct sunlight on the temperature control panel.
4. Energy-saving usage suggestions
| measures | Energy saving effect | Difficulty of implementation |
|---|---|---|
| Install room thermostat | Save 15-20% gas | ★★★ |
| Room control valve | Save 10-15% gas | ★★☆ |
| Clean the system regularly | Improve thermal efficiency by 5-8% | ★☆☆ |
| Lower the temperature by 3-5°C at night | Save 7-10% gas | ★☆☆ |
5. Safety precautions
1. The tightness of the gas pipeline must be checked by a professional before first use.
2. If you smell gas, immediately close the main valve and ventilate it. Do not touch electrical switches.
3. When not in use for a long time, the water stored in the system should be drained to prevent pipes from freezing and cracking.
4. Children should not operate the panel. It is recommended to install a protective cover.
Through the above structured guide, you will not only master the correct method of turning on the wall-mounted boiler heating, but also understand the current hot topics in the field of heating. It is recommended to save this article for emergencies and pay attention to the latest policy notices from local gas companies.